Revert 520 Total Protein Stain Kits for Western Blot Normalization

Revert 520 Total Protein Stain Kits for Western Blot Normalization

Revert 520 Total Protein Stain Kits for Western Blot Normalization

Make Western blot normalization more accurate and reliable with Revert 520 Total Protein Stain, a membrane-based (post-transfer) normalization strategy that stains all protein in your sample. Revert 520 Total Protein Stain works with your existing Western blot workflow and does not require special gels or equipment.

Use the Gold Standard for Western Blot Normalization

Total protein staining is considered the gold standard for Western blot normalization. Revert 520 Total Protein Stain provides linear signal over a broad range of sample concentrations and is compatible with subsequent Western blot immunodetection methods.

  • Accurate Normalization: With a wide linear range, it’s easy to detect Revert 520 stain and your target in the same linear range for accurate normalization.
  • Quick and Compatible: Stain total protein in less than ten minutes on either PVDF or nitrocellulose membranes.
  • Reliable Analysis: Unlike housekeeping proteins, biological variation won’t affect total protein normalization with Revert 520 Total Protein Stain.
Revert 520 staining of PVDF and nitrocellulose membranes
Figure1. Rapid staining with Revert 520 Total Protein Stain. Revert 520 Total Protein Stain provides highly efficient protein staining on nitrocellulose or Immobilon® FL PVDF membranes in under 10 minutes. A dilution series using 20 µg to 313 ng of mouse heart tissue lysate was separated in 4-12% NuPAGE Bis-Tris gels, transferred to nitrocellulose or PVDF membranes, and then imaged using the 520 nm channel of an Odyssey M Imager.
Revert 520 absorbance and emission data chart
Figure 2. Absorbance and emission spectra of the working solution for Revert 520 Total Protein Stain.

Kit Components

The 200 mL Kit (P/N 926-10010) is enough for 20 mini blots and contains:

  • 1 x 200 mL Revert 520 Total Protein Stain
  • 1 x 400 mL Revert 520 Wash Solution
  • 1 x 400 mL Revert Destaining Solution

The 500 mL Kit (P/N 926-10016) is enough for 50 mini blots and contains:

  • 1 x 500 mL Revert 520 Total Protein Stain
  • 1 x 1 L Revert 520 Wash Solution
  • 1 x 1 L Revert Destaining Solution

Selected P/N: 926-10010,926-10016

Price

Quantity

Add to Cart

+ Add to WishlistAdded. Go to Wishlist

Generate an Autoquote

*Includes all LICORBio total protein stains
Frequently bought together: